Venus 7000 Connection Methods 17
1. On the Venus 7000 Shell, click
Configure, and then click on the
RTD Inputs tab.
2. Double-click Input 1 and set up the
port as follows:
Port 1
If DCS is not used (Figure 20) -
Name: “OmniSport”
Source Type: COM PORT
Baud Rate: 19200
Source: COM1
Parity: None
Protocol: Enhanced
Data Bits: 8
Size: 1024
Default Input Template:
OS2-RODEO.itf
Note: COM port numbers may vary
based on the actual port(s) available on the computer.
If DCS is used (Figure 21) -
Name: “OmniSport”
Source Type: UDP/IP SOCKET
Source: “3002”
Protocol: Enhanced
Size: 1024
Default Input Template:
OS2-RODEO.itf
Click OK when finished.
Figure 20: Edit RTD Input1
Figure 21: Edit RTD Input1 (DCS Method)