DataTrac CE-1010 1.2”, 2.1”, 3.2”, 4.2” Display Manual ED11477 Rev 4 1 September 2004 331 32nd Ave PO Box 5128 Brookings SD 57006 Tel 605-697-4
• “0A-_ _ _ _-_ _ _ _” represents an assembly, such as a circuit board and the plate or bracket to which it mounts. A collection of circuit boards wo
Mechanical Installation 2-1Section 2: Mechanical Installation Reference Drawings: Shop Dwg; CE-1010-***-1.2-RG-Thin Mount...D
Mechanical Installation 2-22.2 Z-Bracket Installation for Sectional Display Mounting Review all drawings to determine special requirements. Display
Mechanical Installation 2-3 Each section is labeled with an address and X-Y coordinate. Make sure that the proper section is mounted to the Z-bracket
Section 3: Electrical Installation 3.1 Signal Cables The conductor connector used in the network is an industry standard 6-pin RJ11 or an 8-pin RJ45.
The crimping tool is then used to crimp the RJ11 connector onto the cable. The RJ11 connector is locked into a special socket in the tool. The strippe
3.3 RS422 System A RS422 system requires a signal converter to connect the first sign to the computer. 1. Plug the serial cable’s 25-pin connector
Section 4: Maintenance and Troubleshooting Important Notes: Maintenance and Troubleshooting 4-11. Disconnect power before any repair or maintenance
ED11477 Product 1120 Rev 4- 1 September 2004 DAKTRONICS, INC. Copyright © 2004 All rights reserved. While
4.1 Accessing the Interior of the Display Depending on the overall size of a display system, sectional displays may have two sizes of front access r
To completely remove the LED module panel from the cabinet of the display: Figure 12: LED Module Ribbon Cable Removal 1. Spread the clasps of the
5. Remove the screws located along the top and bottom edge of the module, and lift the PC board off of the rails. Refer to Figure 14. Figure 14: Rem
Display Controller The display controller is mounted to the inside rear of the display cabinet. Refer to Figure 17 for an illustration of the controll
4.3 Controller Address and Test Mode The controller has a set of “DIP” switches on the side of the controller as shown in Figure 18. These DIP switch
Maintenance and Troubleshooting 4-7Entire display is garbled or a section of the display is bad. • Power down, then power up the display. Section of
Maintenance and Troubleshooting 4-8Controller- 422 V1500 0A-1120-0016 Module; CE-10**-4x6-2.1-SBRG 0P-1120-0034 Panel; CE-1010-4x6-2.1-RG 0A-1120
Maintenance and Troubleshooting 4-9When you call the Help Desk, a trained service technician will work with you to solve the equipment problem. You w
Appendix A: Reference Drawings A-1Appendix A: Reference Drawings General Drawings: Generic; System Riser Diagram...
Table of Contents iTable of Contents Section 1: Introduction...
List of Figures ii List of Figures Figure 1: Drawing Label ...
Section 1: Introduction This manual explains the installation and maintenance of Daktronics Panelized DataTrac™ CE-1010 displays. For questions regard
All references to drawing numbers, appendices, figures, or other manuals are presented in bold typeface, as shown below. “Refer to Drawing B-206146 f
Appendix B: Signal Converter B-1Appendix B: Signal Converter
6/30/2004 ED-14413 Page 1 Signal Converters and Loop-back Testing for Direct Connections The following table gives the typical state of the signal con
RS422 Wire Signal Converter The following tables list the jack pin-outs for a wire signal converter: 6/30/2004 ED-14413 Page 2 J4 and J5 – Phoenix P
RS422 Loop-Back Test (Outdoor Displays) Note: This test should be performed with only one jack at a time. Do not connect a loop-back to more than one
RS422 Loop-Back Test (Indoor/Outdoor Displays) All indoor displays and some outdoor displays (AE-3010, AF-3010, AF-3020, and X-1000) use RJ11 plugs or
4. For AE-3010, AF-3010, AF-3020, and X-1000 displays only, disconnect the cable going into the COM module input (J3) on the controller and connect t
Conducting the Venus 1500 Software Test 1. Open Venus 1500 Administrator. 2. Click Network Configuration and open the direct network by clicking o
4. Click [TEST]. 5. If the Transmit LED on the signal converter flickers, the signal is getting to the signal converter. That means that the righ
Introduction 1-3DataTrac displays are character-based indoor LED displays, which are available in tri-color (red, green and amber) characters. This d
Introduction 1-41.4 Part Definitions Com Port: connector on the back of the controller PC. The Com Port is used to control the sign network through
1.5 Daktronics Nomenclature The X-coordinate refers to the LED block placement within a row of characters. To count the placement of the X-coordinate,