Daktronics Venus 1500 Ver 2.x Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Monitore Daktronics Venus 1500 Ver 2.x herunter. Daktronics Venus 1500 Ver 2.x User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 69
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Venus 1500 Controller
Version 2
Operation Manual
ED-12717
InfoNetä, DataTracä, and Galaxyä are trademarks and Glow Cube
â
, Venus
â
and SunSpot are registered
trademarks of Daktronics, Inc. All other trademarks are the property of their respective companies.
ED-12717
Product #1147
Rev. 2 – 18 December 2001
Copyright ã 2001 Daktronics, Inc.
All rights reserved. While every precaution
has been taken in the preparation of this
manual, the publisher assumes no
responsibility for errors or omissions. No part
of this book covered by the copyrights
hereon may be reproduced or copied in any
form or by any means - graphic, electronic,
or mechanical, including photocopying,
taping, or information storage and retrieval
systems - without written permission of the
publisher.
DAKTRONICS, INC.
P.O. Box 5128 331 32
nd
Ave. Brookings, SD 57006
Phone (605) 697-4033 or (877) 605-1112 Fax 697-4444
www.daktronics.com e-mail helpdesk@daktronics.com
Seitenansicht 0
1 2 3 4 5 6 ... 68 69

Inhaltsverzeichnis

Seite 1 - DAKTRONICS, INC

Venus 1500 Controller Version 2 Operation Manual ED-12717 InfoNetä, DataTracä, and Galaxyä are trademarks and Glow Cubeâ, Venusâ an

Seite 2

TCP/IP Connection Type: Display connection across an Ethernet network using the TCP/IP protocol. This type of connection requires a serial server devi

Seite 3 - Table of Contents

When creating a new or opening an existing message/schedule, a small box will be visible to the left of each display type. When the box is filled wit

Seite 5

Section 2: Installation The Venus 1500 software must be installed to a hard disk before use. To install the software onto a computer, follow these

Seite 7 - Section 1: Introduction

Section 3: Configuring the Venus 1500 Controller for First Time Use LThis section is intended to provide basic instructions and examples to configu

Seite 8 - 1.4 Definitions

3.1 Adding a Direct Connection Network The simplest type of network to use is a “direct” network. On this type of network, a dedicated wire connecti

Seite 9 - ENTER> on the keyboard

box. Select Galaxy (LED). The fields in the lower half of the dialog box will adjust based on the selected type of technology. 4. Use the drop-down

Seite 11 - 1.8 Contacting Daktronics

Section 4: The Venus 1500 Administrator The Venus 1500 Administrator is used to configure the various displays, display types, display groups and n

Seite 13 - Section 2: Installation

4.1 Adding a Network The Venus 1500 Administrator 4-2 Click on to activate the network configuration screen. Right-click on any of the network na

Seite 14

1. To use this type of connection, select Dialup Networks in the Network Type field, if it is not already selected. 2. Click on the down arrow next

Seite 15

4. If a Lantronix serial server is being used, click on Use Default. Otherwise, enter the socket number in the corresponding box. 5. Click on [OK] t

Seite 16 - 3.2 Adding the Display Type

4.5 Communication Defaults (Networks) The operator can specify default settings for timeouts, maximum retries and disconnect time for each of the ne

Seite 17 - 3.3 Adding a Display

sizes and colors for the current display technology will be available for selection. If the display is a DataTrac, enter the color (monochrome or tri

Seite 18

1. From the Edit pull-down menu, select New and then Display, or right-click on a display type or another existing display name and select New and th

Seite 19

Editing a Display’s Configuration To modify the settings of an existing display or display group, either right-click on a display or group name at the

Seite 20 - 4.1 Adding a Network

4.9 Time Zone Offset Configuration This allows the time that is sent from the controlling PC to be offset according to Greenwich Mean Time (GMT) if

Seite 22 - 4.4 Remote Database

Section 5: The Venus 1500 Message Studio The Venus 1500 Message Studio creates the messages that will appear on the displays. Text and graphics are

Seite 23 - 4.6 Display Type

Table of Contents Section 1: Introduction... 1-1 1.1 Sys

Seite 24 - 4.7 Displays

5.1 Opening an Existing Message To open an existing message, The Venus 1500 Message Studio 5-2 1. Click on the open button or select Open from t

Seite 25 - LNote: Display types must be

Undo/Redo In Message Studio This tool can be used during the creation of a message to quickly undo an action up to the last ten steps. The Redo comma

Seite 26 - REMOVE]. It is

The Venus 1500 Message Studio 5-4 Message On the toolbar above the Message Studio editing area, four buttons are used to add and delete frames. es tD

Seite 27 - 4.10 Network Testing

The Venus 1500 Message Studio 5-5o invert the colors of a frame (red pixels turn green while green pixels turn red, etc. depending n display color),

Seite 28

Specifying the Entry Effect For text frames, eight entry effects are available: Instant, Scroll Left, Scroll Right, Scroll Up, Scroll Down, Roll Up, R

Seite 29 - Thumbnails

Graphic Toolbar You may notice that a grid is visible on the graphic frame. Each box represents a pixel on the display. The pixel dimensions of the

Seite 30 - 5.2 Creating a New Message

5. Once the progress monitor disappears the import is complete. Adding Text-Objects To place text on a graphic frame: 1. Select the Text button fr

Seite 31 - .4 Frames

The Effect Rate is the speed at which the frame entry effects occur. The Flash Rate is the speed at which flashing text will flash. Set either of thes

Seite 32

5.12 Date, Time & Temperature Data Fields You can insert data fields into a message to display the date, time, temperature (if a temperature sen

Seite 33 - Text Frames

ITF Files The top half of the dialog box is reserved for ITF files. ITF files consist of multiple RTD fields usually generated by the source program (

Seite 34 - 5.7 Graphic Frames

Section 5: The Venus 1500 Message Studio...5-1 5.1 Opening an Existing Message...

Seite 35 - Graphic Toolbar

Horn RTD Field The Horn RTD field controls the display’s horn, if one is installed. It is displayed for use with sporting applications, receiving RTD

Seite 36 - 5.8 Frame Properties

5.15 Adding a Description The operator can add a description to a message to better explain or define what the message consists of or shows. From

Seite 37 - 5.11 Drag and Drop

5.17 Deleting a Message To remove a message from the Message Studio: 1. From the File pull-down menu, select either Open or Save As. A dialog box

Seite 38 - 5.13 Real Time Data (RTD)

Section 6: The Venus 1500 Schedule Studio The Venus 1500 Schedule Studio is used to configure schedules for the display(s). Messages and display br

Seite 39

6.1 Starting a New Schedule To start a new schedule: 1. Select New from the File pull-down menu or click on . The New Schedule dialog box appears.

Seite 40

6.3 Using the Schedule Studio When creating or editing a schedule, there are a few things to keep in mind. · Messages scheduled to run during the

Seite 41 - 5.15 Adding a Description

For example, if a message is to run from 11:00 PM to 1:00 AM, two events need to be entered. Event 1 would run from 11:00 PM (Start Time) to 11:59 PM

Seite 42 - 5.17 Deleting a Message

6.4 Naming & Saving the Schedule To name (or rename) the schedule, click on the File pull-down menu and select Save As. The Save Schedule dialog

Seite 43 - Venus 1500 Schedule Studio

6.6 Exiting the Venus 1500 Schedule Studio To exit the Schedule Studio, select Exit from the File pull-down menu. If any schedules have not been sav

Seite 44 - 6.1 Starting a New Schedule

Entry No. Type Message Name Library Name The Message will Run… 1 Message Christms Holidays 24 hours per day, everyday from Dec. 1 through Dec. 25 2

Seite 45

Choosing the Type of Event ...6-3 Message...

Seite 47 - 6.5 Printing

Section 7: The Venus 1500 Display Manager The Venus 1500 Display Manager controls communications with the displays, is capable of basic display mon

Seite 48 - 6.8 Sample Schedule

Display List The Display List shows all the displays configured for the Venus 1500 network. In addition to each display’s name, the list graphically i

Seite 49

names with the mouse. Select a range of messages by pressing <SHIFT> while choosing the desired messages. Determining what Messages are Runnin

Seite 50

Blanking the Display To stop all messages running on the display, click on . The display will now be completely blank. Retrieving a Message from a D

Seite 51

7.2 Schedule Control Click on . The Venus 1500 Display Manager screen adjusts for Schedule Control. Venus 1500 Display Manager – Schedule Control

Seite 52 - 7.1 Message Control

7.3 Diagnostic Control Click on . The Venus 1500 Display Manager screen adjusts for Diagnostic Control. The Venus 1500 Display Manager 7-6 Diagnos

Seite 53

· InfoNet Displays (excluding model G-1000 Displays): Revision 14 or higher (Firmware Number ED-10133) · Venus 1500 Controlled DataTrac Displays: R

Seite 54

7.5 Exiting the Display Manager To close and exit the Venus 1500 Display Manager, either click on in the upper right corner of the screen, or selec

Seite 55 - 7.2 Schedule Control

Appendix A: System Riser Diagram Appendix A: System Riser Diagram A-1

Seite 56 - 7.3 Diagnostic Control

C.3 Displaying the Font...C-3 Table of Contents iv

Seite 60

Appendix B: Graphics & Special Characters The following table lists special characters that may be used when creating text by holding down on &l

Seite 61

¡ <ALT> <1> <7> <3>█ <ALT> <2> <1> <9>ä <ALT> <2> <4> <0>ã <ALT> <2&g

Seite 62

Electronic DisplayControl Software SystemDaktronics, Inc. 331 32nd Avenue, P.O. Box 5128, Brookings, SD57006 SL111302-04078 Page 1 of 27 Pixel Hig

Seite 63

331 32nd Avenue, PO Box 5128, Brookings, SD 57006Phone: 800-DAKTRONICS or 605-697-4300 Fax: 605-697-4700website: www.daktronics.com email: sales@dak

Seite 64

Appendix C: Using the Venus 1500 Controller to Display Non-English Fonts The Venus 1500 Controller is capable of displaying various non-English fon

Seite 65 - Electronic Display

3. Double-click on Regional Options (Windows 2000) or Regional Settings (Windows NT). Windows 2000 1. At the bottom of the General tab is a sectio

Seite 66 - Graphic Fonts Continued

C.3 Displaying the Font To create a graphic frame with the non-English fonts: 1. Create a new graphic frame in the Venus 1500 Message Studio (ref

Seite 67 - C.2 Initial Settings

Section 1: Introduction The purpose of this manual is to assist in the installation and operation of the Venusâ 1500 Display Network. Refer to Appe

Seite 68

1.4 Definitions The following are terms and definitions used throughout the manual and software. Apply: Clicking [APPLY] on some screens allows chan

Seite 69 - C.3 Displaying the Font

Group: A group is a collection of displays of the same display type. The group may be selected instead of the individual displays. When displays belon

Kommentare zu diesen Handbüchern

Keine Kommentare